EB010
PI: Bondi
Title: OQ208
Session: Oct 1996 (session 3)
Frequency: 1.3 cm
Mode: B
Obs time (UT): 291 EU 07:30(17/10)-15:30(17/10)
Stations: EbJbMhNtOnSm
Processor: Bonn
EU Mk3 Tapes/St.: 1
Comment
To give feedback on this experiment, click here
Experiment Feedback
Effelsberg (Walter Alef at Fri Oct 18 10:34:47 EDT 1996) Success
No known problems.
Metsahovi (Kirsi Karlamaa, Ari Mujunen, Kaj Wiik at Sat Oct 19 09:06:41 EDT 1996) Minor failures
During this experiment we tried to find the cause of our formatter time
jumps and at the same time manually correct them whenever they appeared.
The log contains a lot of setcl#time lines which indicate when
the time was wrong (the last figure, a centisecond offset).
During these times (hopefully less than 10% of the total) the data
will not correlate.
Noto (Corrado Trigilio at Wed Oct 30 05:10:38 EST 1996) Success
No known problems. Sky conditions: variable, from covered at beginning to clear at end.
Onsala (A. Polatidis, J. Conway at Tue Nov 5 05:04:44 EST 1996) Minor failures
Lost first two scans due to a faulty tape. No known problems during the rest of the experiment. Bad weather, heavy rain during most of the experiment.
Jodrell (Alastair Gunn at Thu Nov 7 06:02:38 EST 1996) Minor failures
When started the schedule did not set the VC frequencies properly.
These were set by hand before recordning started. Weather was clear
throughout. Tape MEDI3127 shipped to Bonn on 21/10/96 via Woodcroft.
MPIfR (Scott Aaron at Tue Sep 23 14:16:12 METDST 1997) Failure
Onsala60 100% data loss--weather, no fringes
Simeiz 100% data loss--did not observe
Metsahovi 100% data loss--formatter error
Medicina 100% data loss--no participation in session
Of 7 scheduled antennas, 3 were correlated.